Binocular VNG + vHIT
Life needs balance
The first combined binocular VNG / video Head Impulse Test device, also in simultaneous mode: 97 grams, high-definition infrared cameras and a 9-axis position sensor. With VertiPACS® software, the whole vestibular workup — peripheral and central — in a single instrument.


Overview
VertiGoggles® is a state-of-the-art binocular infrared goggle system for simultaneous recording of eye and head movements, in daylight and in darkness. It is the first combined binocular VNG / video Head Impulse Test device, also in simultaneous mode, supporting the clinician in both diagnosis and reporting of vestibular disorders.
At just 97 grams it is the lightest mask in its class: a clever design that markedly reduces the risk of slippage during manoeuvres and improves wearability. The comfortable, easy-to-clean face cushion is well tolerated by patients even during longer examinations and adapts to different face shapes, paediatric patients included.
A pair of magnetic occluders perfectly excludes ambient light and comes off in one gesture to move between dark-room and fixation testing; the built-in LED provides a software-controlled fixation target.
Technical specifications
| Weight | 97 g |
|---|---|
| Configuration | Binocular, VNG + vHIT |
| Cameras | High-definition infrared |
| Sampling rate | up to 250 Hz |
| Inertial sensor | 9-axis |
| Occluders | Magnetic, removable |
| Fixation target | Built-in LED, software controlled |
| Data interface | GDT 3.1 |
| Marking | CE 0051 |
| Minimum PC spec | 3.5 GHz CPU · 8 GB RAM · 200 GB · USB · Bluetooth · Windows 10 Home 64-bit |
The system is modular: you start from the mask and add the software modules you need over time — caloric, positional, HIMP and SHIMP, advanced oculomotricity, VOR, DVA, Skew Deviation, 3D torsional nystagmus — without ever replacing the hardware.

Innovations
Complete binocular system
Nystagmography and video Head Impulse Test in the same device, with a single stable, artefact-immune calibration.
3D eye movement detection
Reliable, real-time eye tracking with analysis of horizontal, vertical and torsional movements.
Simultaneous left/right eye tracking
Every test records both eyes at once: no trial to repeat for the other side, and the left/right comparison is immediate.
Synchronised data and playback
Eye movement video, scene video, nystagmus plot and slow phase velocity, captured and replayed together.
High-definition IR camera
Recording in daylight and darkness, with an integrated software-controlled fixation target. Sampling rate up to 250 Hz.
9-axis position sensor
Accurate head movement detection, essential for vHIT and positional testing.
Integrated functional assessment
DVA module for dynamic visual acuity and Skew Deviation Test to identify central disorders.
VOR rehabilitation exercises
VOR training: software-guided vestibulo-ocular reflex exercises, to carry on after the assessment with the same instrument.
VertiPACS® — the software platform
VertiPACS® is the integrated platform for the whole ZEHNIT vestibular range: patient database, networked access to the same file from different workstations, GDT 3.1 interface for demographics and results, print or PDF reports with your own logo, editing and playback of every test with its matching video.



| VNG | Gaze, Supine Roll, Dix-Hallpike, caloric and custom tests: as a bundle or as single modules |
|---|---|
| vHIT | Horizontal and vertical Head Impulse Test (HIMP) · horizontal SHIMP, a vHIT add-on also available as a later upgrade |
| Standard oculomotor | Optokinetic, pursuit, saccade and gaze holding tests |
| Advanced oculomotor | Gap, overlap, anti-, predictive and memory saccades, predictive pursuit, step-ramp — designed mainly for research |
| Binocular eye tracking | Recording of both eyes during gaze direction, single tests, head impulse, optokinetic, smooth pursuit, saccades and gaze holding |
| Torsional 3D | Torsional nystagmus in gaze, positional and custom tests · Ocular Counter-Roll: torsional eye movements in response to lateral head tilt |
| Skew | Test of Skew: vertical eye deviation, binocular eye tracking included |
| VOR | VVOR (visually enhanced VOR), VORS (VOR suppression) and VAT (vestibular autorotation test) |
| DVA | Dynamic visual acuity with a wireless numeric keypad (Bluetooth or 2.4 GHz dongle); requires an additional monitor of at least 200 PPI |
| Documentation | Structured dizziness history, clinical findings (otoscopy, vestibulospinal tests, vision, blood tests) and images — eardrum, fundus, X-rays — in the database and the report |
| Clinical scales | DHI, VSS, VADL and BBS, as a bundle or singly · SPPB (Short Physical Performance Battery) |
| Export and stations | MP4 video of eyes and scene, charts and tables, raw data as CSV · viewing station for editing, playback, reports and GDT, licensed on a USB key |
Configure your VertiGoggles: up to three configurations
Build up to three different configurations to be quoted side by side. Configuration 1 is always included; 2 and 3 switch on as soon as you tick a module in their column, or by pressing “switch on” at the top.
| Module | |||
|---|---|---|---|
| CB.VP.VGincludedVertiGoggles — binocular IR camera mask | |||
| CB.VP.CVertiPACS — caloric tests | |||
| CB.VP.HITVertiPACS — Head Impulse Test HIMP | |||
| CB.VP.SHIMPVertiPACS — Head Impulse Test SHIMP | |||
| CB.VP.VNGVertiPACS — VNG and optokinetics | |||
| CB.VP.VNG+VertiPACS — VNG and optokinetics, advanced | |||
| CB.VP.REPVertiPACS — DHI, reporting and advanced archiving | |||
| CB.VP.VIDEOMP4 recording of eye movement | |||
| CB.VP.SETSimultaneous eyetracking — recording in both eyes during gaze direction, positional, vHIT, optokinetic, pursuit, saccadic and gaze tests | |||
| CB.VP.3DTTorsional nystagmus — recording in gaze, positional and Ocular Counter-Roll tests | |||
| CB.VP.OCROcular Counter-Roll — torsional movements in response to lateral head tilt | |||
| CB.VP.SDTSkew Deviation Test — recording of vertical eye divergence | |||
| CB.VP.DVADVA — dynamic visual acuity, with wireless numeric keypad | |||
| CB.VP.VVORVVOR — visually enhanced vestibulo-ocular reflex | |||
| CB.VP.VORSVORS — vestibulo-ocular reflex suppression | |||
| CB.VP.VATVAT — vestibular autorotation test | |||
| CB.VP.DOCDocumentation — structured history, clinical findings and images in the report | |||
| CB.VP.SCALEClinical scales — DHI, VSS, VADL and BBS | |||
| CB.VP.SPPBSPPB — Short Physical Performance Battery | |||
| CB.VP.VIEWViewing station — extra workstation for editing, playback, reports and GDT |
The CB.VP.VG binocular mask is the only mandatory, indispensable part of the system: it is the hardware base every software module runs on, so it stays selected. All other modules are optional and can be added at any time after purchase, without replacing the hardware.
Prices are not published: every configuration is quoted against the clinical case.
Interested in this system?
Add it to your request and receive information and a quote, or request a demo with one of our clinical engineers. On-site installation and training are included.