Binocular VNG + vHIT

Life needs balance

The first combined binocular VNG / video Head Impulse Test device, also in simultaneous mode: 97 grams, high-definition infrared cameras and a 9-axis position sensor. With VertiPACS® software, the whole vestibular workup — peripheral and central — in a single instrument.

VertiGoggles binocular mask, front view
Binocular eye tracking: each eye has its own IR camera.
VertiGoggles worn by a patient during a head impulse test

Overview

VertiGoggles® is a state-of-the-art binocular infrared goggle system for simultaneous recording of eye and head movements, in daylight and in darkness. It is the first combined binocular VNG / video Head Impulse Test device, also in simultaneous mode, supporting the clinician in both diagnosis and reporting of vestibular disorders.

At just 97 grams it is the lightest mask in its class: a clever design that markedly reduces the risk of slippage during manoeuvres and improves wearability. The comfortable, easy-to-clean face cushion is well tolerated by patients even during longer examinations and adapts to different face shapes, paediatric patients included.

A pair of magnetic occluders perfectly excludes ambient light and comes off in one gesture to move between dark-room and fixation testing; the built-in LED provides a software-controlled fixation target.

Technical specifications

Weight97 g
ConfigurationBinocular, VNG + vHIT
CamerasHigh-definition infrared
Sampling rateup to 250 Hz
Inertial sensor9-axis
OccludersMagnetic, removable
Fixation targetBuilt-in LED, software controlled
Data interfaceGDT 3.1
MarkingCE 0051
Minimum PC spec3.5 GHz CPU · 8 GB RAM · 200 GB · USB · Bluetooth · Windows 10 Home 64-bit

The system is modular: you start from the mask and add the software modules you need over time — caloric, positional, HIMP and SHIMP, advanced oculomotricity, VOR, DVA, Skew Deviation, 3D torsional nystagmus — without ever replacing the hardware.

The VertiGoggles mask with its infrared cameras and magnetic occluders

Innovations

Complete binocular system

Nystagmography and video Head Impulse Test in the same device, with a single stable, artefact-immune calibration.

3D eye movement detection

Reliable, real-time eye tracking with analysis of horizontal, vertical and torsional movements.

Simultaneous left/right eye tracking

Every test records both eyes at once: no trial to repeat for the other side, and the left/right comparison is immediate.

Synchronised data and playback

Eye movement video, scene video, nystagmus plot and slow phase velocity, captured and replayed together.

High-definition IR camera

Recording in daylight and darkness, with an integrated software-controlled fixation target. Sampling rate up to 250 Hz.

9-axis position sensor

Accurate head movement detection, essential for vHIT and positional testing.

Integrated functional assessment

DVA module for dynamic visual acuity and Skew Deviation Test to identify central disorders.

VOR rehabilitation exercises

VOR training: software-guided vestibulo-ocular reflex exercises, to carry on after the assessment with the same instrument.

VertiPACS® — the software platform

VertiPACS® is the integrated platform for the whole ZEHNIT vestibular range: patient database, networked access to the same file from different workstations, GDT 3.1 interface for demographics and results, print or PDF reports with your own logo, editing and playback of every test with its matching video.

Head Impulse Test: video of both eyes, eye/head velocity curves and head position in real time.
vHIT · HIMPHead Impulse Test: video of both eyes, eye/head velocity curves and head position in real time.
Nystagmus, slow phase velocity, eye and scene video and a 3D head model on one screen.
VNG · synchronised dataNystagmus, slow phase velocity, eye and scene video and a 3D head model on one screen.
Gain and asymmetry of all six semicircular canals, with corrective saccades.
vHIT · 6 canalsGain and asymmetry of all six semicircular canals, with corrective saccades.
VNGGaze, Supine Roll, Dix-Hallpike, caloric and custom tests: as a bundle or as single modules
vHITHorizontal and vertical Head Impulse Test (HIMP) · horizontal SHIMP, a vHIT add-on also available as a later upgrade
Standard oculomotorOptokinetic, pursuit, saccade and gaze holding tests
Advanced oculomotorGap, overlap, anti-, predictive and memory saccades, predictive pursuit, step-ramp — designed mainly for research
Binocular eye trackingRecording of both eyes during gaze direction, single tests, head impulse, optokinetic, smooth pursuit, saccades and gaze holding
Torsional 3DTorsional nystagmus in gaze, positional and custom tests · Ocular Counter-Roll: torsional eye movements in response to lateral head tilt
SkewTest of Skew: vertical eye deviation, binocular eye tracking included
VORVVOR (visually enhanced VOR), VORS (VOR suppression) and VAT (vestibular autorotation test)
DVADynamic visual acuity with a wireless numeric keypad (Bluetooth or 2.4 GHz dongle); requires an additional monitor of at least 200 PPI
DocumentationStructured dizziness history, clinical findings (otoscopy, vestibulospinal tests, vision, blood tests) and images — eardrum, fundus, X-rays — in the database and the report
Clinical scalesDHI, VSS, VADL and BBS, as a bundle or singly · SPPB (Short Physical Performance Battery)
Export and stationsMP4 video of eyes and scene, charts and tables, raw data as CSV · viewing station for editing, playback, reports and GDT, licensed on a USB key

Configure your VertiGoggles: up to three configurations

Build up to three different configurations to be quoted side by side. Configuration 1 is always included; 2 and 3 switch on as soon as you tick a module in their column, or by pressing “switch on” at the top.

Module
CB.VP.VGincludedVertiGoggles — binocular IR camera mask
CB.VP.CVertiPACS — caloric tests
CB.VP.HITVertiPACS — Head Impulse Test HIMP
CB.VP.SHIMPVertiPACS — Head Impulse Test SHIMP
CB.VP.VNGVertiPACS — VNG and optokinetics
CB.VP.VNG+VertiPACS — VNG and optokinetics, advanced
CB.VP.REPVertiPACS — DHI, reporting and advanced archiving
CB.VP.VIDEOMP4 recording of eye movement
CB.VP.SETSimultaneous eyetracking — recording in both eyes during gaze direction, positional, vHIT, optokinetic, pursuit, saccadic and gaze tests
CB.VP.3DTTorsional nystagmus — recording in gaze, positional and Ocular Counter-Roll tests
CB.VP.OCROcular Counter-Roll — torsional movements in response to lateral head tilt
CB.VP.SDTSkew Deviation Test — recording of vertical eye divergence
CB.VP.DVADVA — dynamic visual acuity, with wireless numeric keypad
CB.VP.VVORVVOR — visually enhanced vestibulo-ocular reflex
CB.VP.VORSVORS — vestibulo-ocular reflex suppression
CB.VP.VATVAT — vestibular autorotation test
CB.VP.DOCDocumentation — structured history, clinical findings and images in the report
CB.VP.SCALEClinical scales — DHI, VSS, VADL and BBS
CB.VP.SPPBSPPB — Short Physical Performance Battery
CB.VP.VIEWViewing station — extra workstation for editing, playback, reports and GDT
1 configuration to quote

The CB.VP.VG binocular mask is the only mandatory, indispensable part of the system: it is the hardware base every software module runs on, so it stays selected. All other modules are optional and can be added at any time after purchase, without replacing the hardware.

Prices are not published: every configuration is quoted against the clinical case.

Interested in this system?

Add it to your request and receive information and a quote, or request a demo with one of our clinical engineers. On-site installation and training are included.

Other systems in the same family